| Customization: | Available |
|---|---|
| After-sales Service: | 24 H Technical Support and One-Stop Solution. |
| Warranty: | 12months |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency


Installation type | Flange -type |
Nominal diameter (mm) | DN15-DN400 |
Pressure class (MPa) | PN1.6MPa,2.5MPa,4.0MPa,6.3MPa,10.0MPa,16MPa,25MPa ANSI 150LB,300LB,600LB,900LB,1500LB,2500LB |
Use conditions | Ambient temperature:-20℃~65℃, Relative humidity: 5%~90%,Atmospheric pressure: 86~106kPa |
Medium temperature | -45-80℃,-45-250℃,-45-350℃ |
Body material | 304; 316L; HC; special customization |
Sensor material | 304,316L,HC,Special customization |
Accuracy | ±0.5%R,±1.0%R,±1.5%R |
Range ratio | 1:10~1:30 |
Power Supply | +6-24VDC, current ≤ 10mA (485 communication current increases 0 .6mA); Battery-powered: 3.6V lithium battery/0.3mA |
Output signal | Pulse output ; 4-20mA current , Control signal, RS485 (Mod bus -RT U protocol), Hart protocol, control signal IoT ,GPRS, etc . |
Rans mission distance | The distance from the sensor to the display meter can be up to 1000m |
Measurement parameters | Temperature (optional), pressure (optional), instantaneous flow and accumulated flow |
Real-time recording | Daily records; records at fixed intervals |
Explosion-proof level | Explosion-proof type;flameproof type |
Protection level | IP65/ IP66/ IP67 |
Electrical interface | Internal thread M20*1 .5,1/2NPT |
Applicable medium | Liquid; gas; steam |